Post Info TOPIC: All Flo outlet connection


Guest

Status: Offline
Posts: 262
Date:
All Flo outlet connection
Permalink  
 


Do you guys happen to know if I can use a 3/8 in (that is the diameter of both inlet and outlet) hose barb, secured with a hose clamp?  Or do I need a crimped hose end to avoid blowout of the hose clamp.


thank you very much and have a great weekend!

__________________

Brad R. Iannacchione
Soapy Roof, LLC
New Kensington, PA 15068



Premium Member Roof Cleaning Institute Of America Certified Roof Cleaning Specialist-MODERATOR

Status: Offline
Posts: 2142
Date:
Permalink  
 

The suction and the feed on the pump is 1/2 in threaded. Where ya getting the 3/8 from???

I'm using a 3/4 in suction hose with a barbed end on the feed. (trust me, it needs to be fed) and a 1/2 crimped theaded fitting on the feed side. I don't see why you couldn't use a hose clamp and barbed end. Just check it from time to time to make sure it stays tight.



__________________

All Surface Roof Cleaning
Largo FL

(727) 543-3276
Roof Cleaning Video
Tile Roof Cleaning�Palm Harbor�Florida
Larry Millette
 Roof Cleaning & Pressure Washing Florida.

  Roof Cleaners Clearwater, Pressure Washers Florida  Roof Cleaners Saint, Petersburg FL 



Guest

Status: Offline
Posts: 262
Date:
Permalink  
 

Hi Larry,

I have a 3/8 pump. The 1/2" dont fit. I have a 3/4 suction hose crimped to a 3/8 fitting for the feed side, but I need another 3/8 barb for my outlet hose.

Thank you.

__________________

Brad R. Iannacchione
Soapy Roof, LLC
New Kensington, PA 15068



Premium Member Roof Cleaning Institute Of America Certified Roof Cleaning Specialist-MODERATOR

Status: Offline
Posts: 2142
Date:
Permalink  
 

Iannacchione wrote:

Hi Larry,

I have a 3/8 pump. The 1/2" dont fit. I have a 3/4 suction hose crimped to a 3/8 fitting for the feed side, but I need another 3/8 barb for my outlet hose.

Thank you.



I've never seen 3/8 supply and discharge side of the All-Flow. They are always 1/2in threaded. It's part of the mold of the unit. ( Scratching my head) ? ?

 



__________________

All Surface Roof Cleaning
Largo FL

(727) 543-3276
Roof Cleaning Video
Tile Roof Cleaning�Palm Harbor�Florida
Larry Millette
 Roof Cleaning & Pressure Washing Florida.

  Roof Cleaners Clearwater, Pressure Washers Florida  Roof Cleaners Saint, Petersburg FL 



Guest

Status: Offline
Posts: 262
Date:
Permalink  
 

Hey Larry,

I am reading the owners manual on the pump I got. Under specifications it says

Fluid Inlet/Discharge
3/8" NPS Femaile
(BSP or NPT compatible)

Trust me, I have no idea what I am talking about, does that mean I need a 3/8 barb fitting?

__________________

Brad R. Iannacchione
Soapy Roof, LLC
New Kensington, PA 15068



Premium Member Roof Cleaning Institute Of America Certified Roof Cleaning Specialist-MODERATOR

Status: Offline
Posts: 2142
Date:
Permalink  
 

Iannacchione wrote:

Hey Larry,

I am reading the owners manual on the pump I got. Under specifications it says

Fluid Inlet/Discharge
3/8" NPS Femaile
(BSP or NPT compatible)

Trust me, I have no idea what I am talking about, does that mean I need a 3/8 barb fitting?



Do you have the pump in your hand? Look at the theaded ends on the pump. in/out. They are 1/2 in. You can use a male 1/2in barbed to feed 1/2in hose on the discharge side but do yourseld a favor and use a 1/2thread by 3/4 in barbed with a 3/4 in suction hose to feed the pump. Mine had a pump stalling issue in the beginning. It wasn't getting enough chems to supply the pump. Switched it to 3/4 in on the supply and have not had a problem since.

Oh Yea! Whats an owners manual??? LOL

 



-- Edited by Roof Cleaning Palm Harbor FL 727 543 3276 on Saturday 1st of May 2010 09:07:01 AM

__________________

All Surface Roof Cleaning
Largo FL

(727) 543-3276
Roof Cleaning Video
Tile Roof Cleaning�Palm Harbor�Florida
Larry Millette
 Roof Cleaning & Pressure Washing Florida.

  Roof Cleaners Clearwater, Pressure Washers Florida  Roof Cleaners Saint, Petersburg FL 



Guest

Status: Offline
Posts: 262
Date:
Permalink  
 

Larry,

Your post is much appreciated. Thank you.

The reason for my original question is because I took the barbed fittings off of my old Fatboy and they didnt fit the All Flo.

I thought the fittings on the Fatboy were 1/2"?

__________________

Brad R. Iannacchione
Soapy Roof, LLC
New Kensington, PA 15068



Premium Member Roof Cleaning Institute Of America Certified Roof Cleaning Specialist-MODERATOR

Status: Offline
Posts: 2142
Date:
Permalink  
 

OK!!! Maybe my dumb ass is wrong. I could have sworn the in and out line was 1/2 in but it looks like it comes standard with 3/8. My bad. Just use the 3/8 to 1/2 barbed-Feed  and a 3/8 to 3/4 barbed for the supply/suction.... I guess I need to look at mine again...? Hmmm!

http://www.all-flo.com/pdfs/Spec38Exp.pdf



-- Edited by Roof Cleaning Palm Harbor FL 727 543 3276 on Saturday 1st of May 2010 09:29:19 AM

__________________

All Surface Roof Cleaning
Largo FL

(727) 543-3276
Roof Cleaning Video
Tile Roof Cleaning�Palm Harbor�Florida
Larry Millette
 Roof Cleaning & Pressure Washing Florida.

  Roof Cleaners Clearwater, Pressure Washers Florida  Roof Cleaners Saint, Petersburg FL 



Guest

Status: Offline
Posts: 262
Date:
Permalink  
 

Thanks Larry!

I will be driving to Lowes this afternoon to pick em up.

Thank you for your time.

__________________

Brad R. Iannacchione
Soapy Roof, LLC
New Kensington, PA 15068



Guest

Status: Offline
Posts: 1342
Date:
Permalink  
 

You had me wondering there Larry,..as mine are also 3/8" in and out. I have them clamped and no leaks. Clamps are fine,...just don't overtighten them to the point of stripping the clamps holding power. Easy to do so be careful.

Jeff

__________________

Raystown Roof Cleaning
Central, Pa

(814) 644-1396 or 1-800-236-0322

Roof Cleaning Central Pennsylvania

Huntingdon, State College, Lewistown, Altoona









Premium Member Roof Cleaning Institute of America Certified Roof Cleaning Specialist

Status: Offline
Posts: 404
Date:
Permalink  
 

That's why they call them  a 3/8'' pump instead of a 1/2 " air pump.confuse

__________________

 

ALABAMA PRO WASH

http://www.roofcleaningalabama.com

EMAIL: ANDY@ALABAMAPROWASH.COM

205-799-9069



guest

Status: Offline
Posts: 2083
Date:
Permalink  
 

I use threaded connectors and pvc, works good for over a year this way. Really whatever you want to hook up to it will work. If you use barbs and clamps and you have a suction problem one day it will probably be a minor air draw leak on the intake side. Re tighten the clamps and problem solved. This will be true with any pump.

__________________

Bill Booz

Accuwash LLC

Cell-240-425-2845

 