Permalink  
 


We had an interesting 1st year cleaning roofs.  A lot of ups & downs.  For thoses who are just getting into roof cleaning or are considering starting to my only advise is to read, read, and read some more.  There is a lot of knowledge that you will need to absorb.

On one of our first jobs this year we were cleaning a home with a manser style roof. Danny was on the roof itself doing the shoot.  As we proceeded to the back of the home his hands started to feel tinglely and he started to feel slightly nauseous.  He took off his rubber gloves and touched the metal coupling on the hose itself and got quite a jolt.  Our ladder, the gutters, everything metal has HOT with electicity.  He ended up jumping off the roof from about 10' off the ground and fortunately hasn't hurt, but it took a couple of hours before he felt normal again from the electric shock itself.  We called the homeowner and told what happened and he informed us that he had new gutters installed in the spring.  The next day they were inspected and they found that the installer had struck a wire during installation.

I'm not sure how many of you have experienced this or how we could have avoided this situation.  All I know is Danny was very lucky and a damn good jumper.

Mike
Indiana Roof Cleaning LLC

__________________
Danny and Mike Spiczenski




Indiana Roof Cleaning
Safe Roof Cleaning
Non Pressure Roof Cleaning Indianapolis
Black Streak Removal


www.StopTheStreaking.com







Premium Member Roof Cleaning Institute Of America

Status: Offline
Posts: 230
Date:
Permalink  
 

138394,138394,138394,138394,138394,138394,138394,138394,138394,

Well said...all I could add is........Read summore...

& join the RCIA!!!

Oh yea I almost forgot....Go Hogs!!!!


-- Edited by Arkansas Roof Cleaning (501) 681 3355 on Tuesday 14th of December 2010 09:07:23 AM

__________________

Arkansas Roof & House Cleaning Little Rock

www.ArkansasRoofRenew.com

www.ArkansasCleanMyHouse.com

Chris Kaeppel -501 681-4447
Al Williams    -501 681-3355



guest

Status: Offline
Posts: 2083
Date:
Permalink  
 

This can actually be a common problem. We have been shocked by gutters a few times over the years. Now that your aware of it you can train your employees not to jump off the roof. Always good to inform the homeowner. This is great advice exampling how there are always unexpecteds and the more prepared a service tech is the less likely they will get hurt or cause damage.

__________________

Bill Booz

Accuwash LLC

Cell-240-425-2845

 



Guest

Status: Offline
Posts: 645
Date:
Permalink  
 

Indiana Roof Cleaners wrote:

We had an interesting 1st year cleaning roofs.  A lot of ups & downs.  For thoses who are just getting into roof cleaning or are considering starting to my only advise is to read, read, and read some more.  There is a lot of knowledge that you will need to absorb.

On one of our first jobs this year we were cleaning a home with a manser style roof. Danny was on the roof itself doing the shoot.  As we proceeded to the back of the home his hands started to feel tinglely and he started to feel slightly nauseous.  He took off his rubber gloves and touched the metal coupling on the hose itself and got quite a jolt.  Our ladder, the gutters, everything metal has HOT with electicity.  He ended up jumping off the roof from about 10' off the ground and fortunately hasn't hurt, but it took a couple of hours before he felt normal again from the electric shock itself.  We called the homeowner and told what happened and he informed us that he had new gutters installed in the spring.  The next day they were inspected and they found that the installer had struck a wire during installation.

I'm not sure how many of you have experienced this or how we could have avoided this situation.  All I know is Danny was very lucky and a damn good jumper.

Mike
Indiana Roof Cleaning LLC



Wow, he is seriously lucky I've never been hit on a roof before but I was jolted cleaning a deck one time, the home owner had an enclosed portion and there was a bar with a radio set up in there and the radio wiring was exposed and taped up touching the metal frame of the deck encolsure and he walks out and is all " hey guys want some tunes?" Flicks a switch and I go flying back and don't remember it.
My helper was all freaked out but I was fine, I was concious but really out of it. The home owner wanted to call an ambulence I told him to call an electrician.

Wet deck plus exposed wires= shock. I had shoes on, maybe my feet were too wet, I also had a metal deck wand in my hand.

I have never been that tired and jittery in all of my life. Very wierd feeling. Hope it never happens again.
It makes me look harder now and ask more questions about safety though, not just electric either. You don't want to have to learn every lesson the hard way.

I agree,138394, great post!

__________________


Bucks County PA Roof Cleaning

267-477-1107
Free Your Pennsylvania Roof From Fungus
Serving all of Bucks and Montgomery Counties and surrounding areas of Philadelphia
Chalfont, PA 18914




Forum Administrator Premium Member Roof Cleaning Institute of America Certified Roof Cleaning Specialist

Status: Offline
Posts: 2720
Date:
Permalink  
 

You can always get a voltage tester and start testing the downspouts for voltage. Push a long screwdriver in the ground for your ground and it will show voltage if any's present. We used to test the ground wire on all joint use poles at BellSouth before climbing them. Sometimes the ground wire would be broken and you sure don't want to complete the circuit on 10k volts. We also test all mobile homes before installing a phone. Sometimes their also hot.

__________________

 

Roof Cleaning Louisville Kentucky | Qwik Roof Cleaners
Louisville Kentucky 

 Click here to visit our website

Roof Stain Removal Louisville Ky

CONCRETE CLEANING / FENCE / DECK RESTORATION

HOT WATER STEAM CLEANING

502-773-1730



Roof Cleaning Institute Of America Master Certified Roof Cleaning Instructor

Status: Offline
Posts: 504
Date:
Permalink  
 

I keep a voltage tester in my tool box on the trailer. Anytime I work around
a metal structure or Gutters, I test it first.
Here is a link to the one I have.

http://www.amazon.com/Gardner-Bender-GVD-505A-Non-Contact-Voltage/sim/B000BQWU3S/2



Fixed your link - Brian

-- Edited by The Roof Cleaners of Chester County Pennsylvania 610-842-2104 on Tuesday 14th of December 2010 01:34:42 PM

__________________

 


Forum Administrator Premium Member Roof Cleaning Institute of America Certified Roof Cleaning Specialist

Status: Offline
Posts: 2720
Date:
Permalink  
 

138394,138394,138394,  Everybody should have on on their truck. Takes 5 seconds to save your life.
Gary

__________________

 

Roof Cleaning Louisville Kentucky | Qwik Roof Cleaners
Louisville Kentucky 

 Click here to visit our website

Roof Stain Removal Louisville Ky

CONCRETE CLEANING / FENCE / DECK RESTORATION

HOT WATER STEAM CLEANING

502-773-1730



none

Status: Offline
Posts: 692
Date:
Permalink  
 

Been There, Done That, Bought The T-Shirt, Smoked The Doobie. confuse Happened in my first year of biz as well!

AC


__________________


guest

Status: Offline
Posts: 1578
Date:
Permalink  
 

garyw wrote:

You can always get a voltage tester and start testing the downspouts for voltage. Push a long screwdriver in the ground for your ground and it will show voltage if any's present. We used to test the ground wire on all joint use poles at BellSouth before climbing them. Sometimes the ground wire would be broken and you sure don't want to complete the circuit on 10k volts. We also test all mobile homes before installing a phone. Sometimes their also hot.



+1 on mobile homes!! It will charge the entire shell of the home!! Bad grounds too!!

 



-- Edited by Washed-up on Wednesday 15th of December 2010 09:54:08 PM

__________________

Dwayne Miller
FLORIDAWASH
safe roof cleaning

Lake Marion Citrus & Sumter Counties in Florida


facebook-logo.jpg twitter_logo_small.png



Guest

Status: Offline
Posts: 645
Date:
Permalink  
 

honestly what else... Im sitting here thinking about it..what else, I mean we have one of the most dangerous professions out there.

Safety first or nothing's second

__________________


Bucks County PA Roof Cleaning

267-477-1107
Free Your Pennsylvania Roof From Fungus
Serving all of Bucks and Montgomery Counties and surrounding areas of Philadelphia
Chalfont, PA 18914




guest

Status: Offline
Posts: 1578
Date:
Permalink  
 

BCRoofClean wrote:

honestly what else... Im sitting here thinking about it..what else, I mean we have one of the most dangerous professions out there.

Safety first or nothing's second




 NICE!!



__________________

Dwayne Miller
FLORIDAWASH
safe roof cleaning

Lake Marion Citrus & Sumter Counties in Florida


facebook-logo.jpg twitter_logo_small.png



Guest

Status: Offline
Posts: 91
Date:
Permalink  
 

Guys,

Thank You for your responses.   I figured we weren't the only ones to run into this type of situation.  I appreciate the input,  a voltage tester definately sounds like a must especially with any type of metal structure. 

It is not easy to do some of the roofs out there today.  Most artitects seem to enjoy big, expensive, odd shaped, and not always easy to clean roofs on homes today.


Mike
Indiana Roof Cleaning LLC

__________________
Danny and Mike Spiczenski




Indiana Roof Cleaning
Safe Roof Cleaning
Non Pressure Roof Cleaning Indianapolis
Black Streak Removal


www.StopTheStreaking.com





Page 1 of 1  sorted by
 
Quick Reply

Please log in to post quick replies.

Tweet this page Post to Digg Post to Del.icio.us


Create your own FREE Forum
Report Abuse
Powered by ActiveBoard