Wiring the fatboy (had to buy a replacement).
Permalink  
 


Hello, I wish I wasn't such a dud when it came to wiring or rewiring, but I am. I called Bob from Pressuretek since I brought this unit from him, completely wired. It's been used less than 10 times and the pump blew. It was rinsed everytime, but nonetheless, I brought another one so I could send the busted one back and still have a replacement. Bob told me to basically just look at the current setup and copy what I see. I felt like I was bothering him and didn't exactly get the feeling that he wanted to deal with me. Well, okay, I tried to duplicate what I saw, but the setups look different to me. Before calling again, I'd like to see if you guys could help me at all.

Have these pumps changed? There is an obvious difference in these pumps, the newest one has an additional piece that makes it so I am unsure of how to duplicate the wiring. It would have been nice to at least receive a wiring diagram to see how to wire the new pump, but I was told that one does not exist. If anyone has a wiring diagram or something that I could follow, that would be great.



-- Edited by Phil Rogers on Sunday 12th of September 2010 10:27:18 PM

Attachments
__________________
Extreme Cleaning Solutions (410) 980-1053
Phil Rogers
Click Here to View Our Website
Click Here for an Instant Quote
Roof Cleaning and Pressure Washing in Anne Arundel County, and Howard County, Maryland


Premium Member Roof Cleaning Institute of America Certified Roof Cleaning Specialist

Status: Offline
Posts: 2070
Date:
Permalink  
 

What size tips were/are you using? Did you include an inline fuse on your wiring design?

__________________

Ed Thompson
Woodbridge N.J.

(732) 726-9261
Digital Brochure

 

 

 



Guest

Status: Offline
Posts: 1607
Date:
Permalink  
 

Hi Phil.   I just ordered another fatboy (back up unit) on Friday and am now curious if it'll be like your new one.  BTW - Bob had gone home sick on Friday - may explain why he wasn't very talkative.  Just a possibility.

There should only be two leads loose on these pumps;   A 14 AWG ground wire and a 14 AWG 12vdc wire.  It should only be a matter of replacing the connections one for one, and the plumbing of course.   (You may have to adjust the pressure switch once that's done.)

Are there more than two leads from that pump?  If not, it should be straight forward.  I can take some pics of mine and send them to you tomorrow afternoon/evening if that'll help.


__________________
 
American-ProTech 
Proudly serving Northern Virginia, DC, Maryland and Atlanta
 (571) 250-9650 VA
 (240) 398-3800 MD
(404) 858-4888 Atlanta GA


Guest

Status: Offline
Posts: 135
Date:
Permalink  
 

You should only have a black and a red wire coming out. Hook red to pos and black to neg. The difference you see is a relay that has been added to keep the motor load off the pressure switch.

__________________
Russ Johnson
Southside Equipment, Inc
Pressure Cleaning Equipment Service Chemicals
Louisville, KY
888-243-6506


Guest

Status: Offline
Posts: 1213
Date:
Permalink  
 

The relays always been there. I got one of the first ones.

__________________




Guest

Status: Offline
Posts: 308
Date:
Permalink  
 

Bob has always been real good to me over the phone. He has helped me fix a few problems over the phone. You must of caught him on a bad day(it happen to all of us). You can always ask for Andy as well there he's just as good as Bob.

__________________

Jim Fuller
A Fuller Service
5 Derry Lane
Latham NY 12110
518-526-5554

http://www.aroofwash.com/

christmaslightsofalbany.com

 



guest

Status: Offline
Posts: 1202
Date:
Permalink  
 

There are only two leads, one pos and one neg, but the positive wire on the old pump seems to be cut and then branched off in to a separate connection as well. Since the pumps were visually different, a little bit, I was unsure of what to do. I will give it another shot tonight.

Ted, would you mind sending me a few pictures?

Thanks for the replies.

__________________
Extreme Cleaning Solutions (410) 980-1053
Phil Rogers
Click Here to View Our Website
Click Here for an Instant Quote
Roof Cleaning and Pressure Washing in Anne Arundel County, and Howard County, Maryland


Guest

Status: Offline
Posts: 135
Date:
Permalink  
 

That looks like an awfull lot of corossion for being used 10 times!!! Make sure theres not roof cleaner sitting in the box with the pump. Did you drill holes in the pump box so it can drain? Wont hurt to rinse the outside of  the pump with fresh water if it gets roof cleaner on it. Just sayin.

__________________
Eastern Roof Cleaning & Exteriors
www.easternroofcleaning.com
908-674-3392
Stewartsville, NJ 08886


guest

Status: Offline
Posts: 1202
Date:
Permalink  
 

Yeah, that was after the pump busted, I threw my hands up and just let it sit after rinsing our my truck. Before the pump blew, there wasn't any corrosion on it.

__________________
Extreme Cleaning Solutions (410) 980-1053
Phil Rogers
Click Here to View Our Website
Click Here for an Instant Quote
Roof Cleaning and Pressure Washing in Anne Arundel County, and Howard County, Maryland


Guest

Status: Offline
Posts: 1607
Date:
Permalink  
 

Phil Rogers wrote:

There are only two leads, one pos and one neg, but the positive wire on the old pump seems to be cut and then branched off in to a separate connection as well. Since the pumps were visually different, a little bit, I was unsure of what to do. I will give it another shot tonight.

Ted, would you mind sending me a few pictures?

Thanks for the replies.




Phil - I have the pics for you.  Do you want me to send them to PhilRogers@extremecleaningsolutions.biz which I found on your website or is there another email address you'd prefer?

As an aside, my Fatboy looks like your original one. There is no visible relay assembly where the wires protrude.



__________________
 
American-ProTech 
Proudly serving Northern Virginia, DC, Maryland and Atlanta
 (571) 250-9650 VA
 (240) 398-3800 MD
(404) 858-4888 Atlanta GA


Guest

Status: Offline
Posts: 1213
Date:
Permalink  
 

Ted can you post a picture of yours?

__________________




Guest

Status: Offline
Posts: 1607
Date:
Permalink  
 

Confident Roof Cleaning Houston TX wrote:

Ted can you post a picture of yours?




Sure.  Here ya go.  Not sure if it matters, but it was made on 12/09, as shown on the housing.

Phil - I have a series of about 4 pics for you tracking the wires from the pump.



Attachments
__________________
 
American-ProTech 
Proudly serving Northern Virginia, DC, Maryland and Atlanta
 (571) 250-9650 VA
 (240) 398-3800 MD
(404) 858-4888 Atlanta GA


guest

Status: Offline
Posts: 1202
Date:
Permalink  
 

Thanks for all of the help, everyone. Lori, thank you very much. I will call if we get stuck while working on this today. You may have earned a new customer.

__________________
Extreme Cleaning Solutions (410) 980-1053
Phil Rogers
Click Here to View Our Website
Click Here for an Instant Quote
Roof Cleaning and Pressure Washing in Anne Arundel County, and Howard County, Maryland


guest

Status: Offline
Posts: 1202
Date:
Permalink  
 

Hey Ted, that looks like my original setup (without the relay), which is where I was confused because I couldn't exactly duplicate the connections. I work on computer networks full time, this is a part time business, so I am nowhere near a pump or wiring genius! :)



__________________
Extreme Cleaning Solutions (410) 980-1053
Phil Rogers
Click Here to View Our Website
Click Here for an Instant Quote
Roof Cleaning and Pressure Washing in Anne Arundel County, and Howard County, Maryland
Page 1 of 1  sorted by
 
Quick Reply

Please log in to post quick replies.

Tweet this page Post to Digg Post to Del.icio.us


Create your own FREE Forum
Report Abuse
Powered by ActiveBoard