Hey guys, I was wondering if restricting the flow of water going out of my hose will affect in any way the All-flo that I have.For example, if I want to cut my flow to 1/2,if I am up close to the surface, or close to an edge, does the back pressure harm the pump in anyway?May seem like a dumb question for some, but I have no previous experience with this setup. Thanks Mike

__________________
Mike


Premium Member Roof Cleaning Institute Of America Certified Roof Cleaning Specialist-MODERATOR

Status: Offline
Posts: 2142
Date:
Permalink  
 

misuchel wrote:

Hey guys, I was wondering if restricting the flow of water going out of my hose will affect in any way the All-flo that I have.For example, if I want to cut my flow to 1/2,if I am up close to the surface, or close to an edge, does the back pressure harm the pump in anyway?May seem like a dumb question for some, but I have no previous experience with this setup. Thanks Mike



No it will not hurt the pump.

 



__________________

All Surface Roof Cleaning
Largo FL

(727) 543-3276
Roof Cleaning Video
Tile Roof Cleaning�Palm Harbor�Florida
Larry Millette
 Roof Cleaning & Pressure Washing Florida.

  Roof Cleaners Clearwater, Pressure Washers Florida  Roof Cleaners Saint, Petersburg FL 



guest

Status: Offline
Posts: 2083
Date:
Permalink  
 

That's one of the benefits of AOD pumps...they are made for back pressure in order to shut off. When the air and liquid pressure equalizes it enters a mode known as dead headhmm until the pressure is offset again.

__________________

Bill Booz

Accuwash LLC

Cell-240-425-2845

 



Guest

Status: Offline
Posts: 19
Date:
Permalink  
 

Cool. Thanks for the technical help guys.

__________________
Mike


Guest

Status: Offline
Posts: 12
Date:
Permalink  
 

Back pressure does not harm any air diaphragm pump unless the back pressure exceeds the rating of the pump. All-flo pumps can handle up to 120 psi.



__________________
Steve Weirich


guest

Status: Offline
Posts: 157
Date:
Permalink  
 

No your not going to hurt it!



__________________
Mark 941-726-7082


Guest

Status: Offline
Posts: 88
Date:
Permalink  
 

The main thing I've found is watching out for moisture. Make sue you open the desicant filter frequently. It will stoop spraying if moisture build up


__________________



Pro Pressure Clean and Seal
727-432-2501
www.roofsanddecks.com
Pinellas county roof cleaning
Tampa Bay commercial pressure cleaning
http://www.youtube.com/watch?v=DhddIagflH4&feature=channel

Page 1 of 1  sorted by
 
Quick Reply

Please log in to post quick replies.

Tweet this page Post to Digg Post to Del.icio.us


Create your own FREE Forum
Report Abuse
Powered by ActiveBoard